Recommendations and steps to handle "Unconfigured Bad" drive Drives suddenly become Unconfigured Bad on the Intel® RAID Web Console 3 (RWC3). On a fully featured Intel® RAID Controller, a drive becomes unconfigured bad when the Intel® RAID Controller loses communication with the drive temporarily. This can happen when: If you are confident that the drive is healthy, follow the steps below to re-use this drive: The drive then turns from Unconfigured Bad to Foreign state as it consists of the existing RAID configuration. You can choose to either: Do this by selecting Configure then Foreign Configuration from the Controller Actions on the top right. If you are uncertain, remove the drive and run further diagnostics to verify the health status of the drive or replace it with new drive.Why Are Drives Being Marked as “Unconfigured Bad” on the Intel® RAID Web Console 3?
Related Products
This article applies to 23 products
「未構成の不良」ドライブを処理するための推奨事項と手順
インテル® RAID ウェブ・コンソール 3 (RWC3) でドライブが突然未構成不良になります。
フル機能のインテル® RAID Controllerでは、インテル® RAID Controllerが一時的にドライブとの通信を失うと、ドライブが 未構成で不良になります。これは、次の場合に発生する可能性があります。
- ドライブが悪い
- ケーブルが悪いまたは緩んでいる
- 同じドライブを再挿入した後、ドライブを取り外すのが驚きました
ドライブの正常な状態が確認できる場合は、以下の手順に 従って このドライブを再利用してください。
- [ドライブ] タブをクリックします。
- [ + ] をクリックして 、[未構成のドライブ] を展開します。
- 未構成の不良ドライブを選択します。
- [ 要素] の右側にある [ 未構成のグッドを作成 ] をクリック します。
ドライブは既存の RAID 構成で構成されており、未構成の不良状態から外部状態に変わります。
次のいずれかを 選択 できます。
- 外部構成のインポート: コントローラーはこのドライブを使用して、このドライブが元々属していた仮想ドライブ (VD) を再構築します。
- 外部構成をクリアする: ドライブが未構成のグッドとなり、新しいVDの作成に使用できます。
右上にある [コントローラー・アクション] で[設定]、[外部構成]を選択します。
不明確な場合は、ドライブを 取り外 してさらに診断を実行してドライブの状態を確認するか、新しいドライブに 置き換えてください 。